FORMER GERMAN SUBMARINE TYPE XXI |
|||||
SOUNDING TUBES AND VENTS |
|||||
SUMMARY |
|||||
Sounding tubes and venting arrangements continue to be normal in general, but the installation of sounding tubes in drinking water tanks is retained from earlier types of vessels, and one pair of main ballast tanks is provided with inboard vents for use after blowing in order to offset overcompensation. | |||||
July, 1946 |
|||||
PORTSMOUTH NAVAL SHIPYARD, PORTSMOUTH, N. H. |
|||||
- 1 - |
|||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Sounding and venting connections in this type of vessel are as follows: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Inboard vents, with sight glasses and mufflers, are fitted to the regulating tank, regulating bunker and MBT 3. Inboard vents are provided as well on all fuel oil tanks and a further inboard vent is provided for the spray shield over the torpedo tube nozzles. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Vents are provided at the high points in fluid piping systems. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Main vents are discussed in the S29 and S49 sections of the report. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Comments: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Applications are normal in all respects. Much greater use is made, in this type of vessel, of separate sounding and venting tubes than in earlier vessels. The provisions of inboard vents on MBT 3 is unusual, and is explained in the General Information book as being installed to permit reventing after blowing when submerged, without showing a bubble on the surface. In the absence of any pressure gauges or other indication of the condition of this tank, it is thought that the arrangement would be of limited value except in an emergency. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
- 2 - |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||